Cable OSP CAT 6A

cable osp

Cable OSP de categoría 6A, 4 pares, F/UTP, sin gel

Cable horizontal de categoría 6A para instalaciones, con clasificación OSP, 4 pares, conductores de cobre sólido desnudo de 23 AWG, F/UTP – apantallado, sin gel

OSP-Planta Exterior, Cable Horizontal de Premisa, Ethernet hasta 10GBASE-T, Wi-Fi 6, Wi-Fi 5, PoE++, PoE+, PoE, Enivronamientos Ruidosos, HDBaseT, Cámaras IP

Construction Details

CONDUCTOR

Tamaño Tipo Material Numero de pares
23 Solido BC – Cobre 4

INSULATION

Material Código de Color
PO – Polioelefina Blanco & Azul, Blanco & Naranja, Blanco & Verde, Blanco & Café

OUTER SHIELD

Tipo de cubierta Material Cubierta Tipo de Cable
Tape Bi-Laminado (Alum+Poly) 100% 26 AWG (7×34) TC

OUTER JACKET

Separador Material Diámetro Ripcord
Center Member (Patented T-Spline®), EquiBlock™ Barrier Technology PO – Polyolefin 0.29 in (7.4 mm) Si
Diametro de Cable General (Nominal) 0.29 in (7.4 mm)

Electrical Characteristics

ELECTRICALS

Max. Conductor DCR Max. Capacitance Unbalance
82 Ohm/km (25 Ohm/1000ft) 45 pF/100m

DELAY

Frequency Max. Delay Max. Delay Skew Nom. Velocity of Prop.
100 MHz 537.6 ns/100m 45 ns/100m 68%

HIGH FREQUENCY

Frequency [MHz] Max. Insertion Loss (Attenuation) [dB/100m] Min. NEXT [dB] Min. PSNEXT [dB] Min. ACR [dB] Min. PSACR [dB] Min. ACRF (ELFEXT) [dB] Min. PSACRF (PSELFEXT) [dB] Min. RL (Return Loss) [dB] Max./Min. Input Impedance (unFitted) Max./Min. Fitted Impedance Min. PSANEXT [dB] Min. PSAACRF [dB] Min. TCL [dB] Min. ELTCTL [dB]
1 2.1 74.3 72.3 72.2 70.2 67.8 64.8 20.0 105 +/- 10 115 +/- 15 67.0 67.0 40.0 35.0
4 3.8 65.3 63.3 61.5 59.5 55.8 52.8 23.0 105 +/- 10 100 +/- 7 67.0 66.2 40.0 23.0
8 5.3 60.8 58.8 55.4 53.4 49.7 46.7 24.5 100 +/- 22 100 +/- 7 67.0 60.1 40.0 16.9
10 5.9 59.3 57.3 53.4 51.4 47.8 44.8 25.0 100 +/- 22 100 +/- 7 67.0 58.2 40.0 15.0
16 7.5 56.2 54.2 48.8 46.8 43.7 40.7 25.0 100 +/- 22 100 +/- 7 67.0 54.1 38.0 10.9
20 8.4 54.8 52.8 46.4 44.4 41.8 38.8 25.0 100 +/- 22 100 +/- 7 67.0 52.2 37.0 9.0
25 9.4 53.3 51.3 44.0 42.0 39.8 36.8 24.3 100 +/- 22 100 +/- 7 67.0 50.2 36.0 7.0
31.25 10.5 51.9 49.9 41.4 39.4 37.9 34.9 23.6 100 +/- 22 100 +/- 7 67.0 48.3 35.1 5.1
62.5 15.0 47.4 45.4 32.4 30.4 31.9 28.9 21.5 100 +/- 22 100 +/- 7 65.6 42.3 32.0
100 19.1 44.3 42.3 25.2 23.2 27.8 24.8 20.1 100 +/- 22 100 +/- 7 62.5 38.2 30.0
200 27.6 39.8 37.8 12.2 10.2 21.8 18.8 18.0 100 +/- 22 100 +/- 7 58.0 32.2 27.0
250 31.1 38.3 36.3 7.3 5.3 19.8 16.8 17.3 100 +/- 32 100 +/- 7 56.5 30.2 26.0
300 34.3 37.1 35.1 2.9 0.9 18.3 15.3 16.8 100 +/- 32 100 +/- 7 55.3 28.7 25.2
350 37.2 36.1 34.1 16.9 13.9 16.3 100 +/- 32 100 +/- 7 54.3 27.3 24.6
400 40.1 35.3 33.3 15.8 12.8 15.9 100 +/- 32 100 +/- 7 53.5 26.2 24.0
450 42.7 34.5 32.5 14.7 11.7 15.5 100 +/- 32 100 +/- 7 52.7 25.1 23.5
500 45.3 33.8 31.8 13.8 10.8 15.2 100 +/- 32 100 +/- 7 52.0 24.2 23.0

VOLTAGE

Voltage Rating
300 V

Mechanical Characteristics

TEMPERATURE

Operating Installation Storage
-20°C To +70°C 0°C To +60°C -40°C To +75°C

BEND RADIUS

Installation Min.
2.9 in (74 mm)
Max. Pull Tension 25 lbs (11 kg)
Bulk Cable Weight 33 lbs/1000ft (49 kg/km)

Standards and Compliance

Environmental Suitability Outdoor – Water Exposure, Outdoor
IEEE Compliance IEEE 802.3bt Type 1, Type 2, Type 3, Type 4
Data Category Category 6A
TIA/EIA Compliance ANSI/TIA-568.2-D Category 6A
ISO/IEC Compliance 11801 ed 2.2 (2011) Class EA
CENELEC Compliance Segregation class according EN50174-2 = a

Product Notes

Notes Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0. Not Suitable for Direct Burial. Cable jacket system is specially designed to protect cable core. Cable contains no water-blocking tapes, gels, or powders. Install in accordance with all applicable electrical codes. Maintain jacket integrity throughout installation process. Do not allow water or fluids to penetrate jacket sheath or to enter ends of cable. Ensure ends of cable will be protected from water/fluids after installation. Belden recommends using an entrance demarcation point when transitioning inside buildings with OSP cables. The suggested transition point is the REVConnect core coupler, part number RVACPKUBK-S1.

History

Update and Revision Revision Number: 0.15 Revision Date: 11-01-2022

Hide Specifications

Part Numbers

Item # Color Putup Type Length
DOSP6AF 0101000 Black Reel 1,000 ft